1 / 5
| Performance parameters | |||||
| Sequence | Test ltem | Unit | Test results | Level determination | |
| 1 | Air tightness performance | Air permeability per unit seam length q1 | [cubic m/(m.h)] | 1.4 | Level 6 |
| (under positive pressure of 10Pa) | Air permeability per unit area q2 | [cubic m/(square m.h)] | 2.3 | Level 7 | |
| 2 | Air tightness performance (under negative pressure of 10Pa) | Air permeability per unit seam length q1 | [cubic m/(m.h)] | 1.3 | Level 6 |
| Air permeability per unit area q2 | [cubic m/(square m.h)] | 2.2 | Level 7 | ||
| 3 | Water tightness performance | Pa | 350 | Level 4 | |
| 4 | Wind resistance performance | (Grading detection positive pressure) | kPa | 2.68 | Level 4 |
| Wind resistance performance | kPa | 2.69 | Level 4 | ||
| 5 | Thermal insulation performance | Heat transfer coefficient | W/(square m.K) | 2.2 | Level 6 |